Product information "FA 515 - Dew point sensor "
FA 515 - Dew point sensor
FA 510/515 - Dew point sensor for adsorption dryers
Monitoring a desiccant dryer is critical to increase energy efficiency, ensure product quality, prevent damage to machinery, identify maintenance needs, and achieve cost savings. This contributes to the smooth operation of compressed air systems in various industrial applications.The sensor technology and evaluation electronics of our sensors have undergone continuous improvements. This implies an increased precision at varying ambient temperatures and a higher signal resolution of the sensor. Similar to their predecessor models, the new dew point sensors are characterized by long-lasting stable and reliable measurement results. The sensor element is insensitive to condensation and is protected from direct contact with contaminated particles by the stainless-steel sintered cap.
Downloads
Technical Data sheet dew point sensor FA 510/515 - desiccant driers, PDF( Size: 1.3 MB )
Technical Data sheet dew point sensor FA 510/515 - Service concept of new dew point sensor, PDF( Size: 1.3 MB )
Technical Data FA 510/515
Measuring range | -80…20 °Ctd, -20…50 °Ctd |
Accuracy | ± 1 °C at 50…-20 °Ctd ± 2 °C at -20…-50 °Ctd ± 3 °C at -50…-80 °Ctd |
Pressure range | -1…50 bar Special version up to 500 bar |
Power supply | 24 VDC (10…36 VDC) |
Protection class | IP 66 |
EMC | In acc. with DIN EN 61326-1 |
Operating temperature | -20…70 °C |
Connection | M12, 5-pin |
PC connection | Modbus-RTU interface (RS 485) |
Analogue output | 4…20 mA = -80…20 °Ctd 4…20 mA = -20…50 °Ctd FA 510: 4…20 mA (3-wire) FA 515: 4…20 mA (2-wire) |
Burden for analogue output | < 500 Ω |
Screw-in thread | G 1/2″ Stainless steel Optional: UNF 5/8", NPT 1/2" |
Dimensions | Ø 30 mm, length approx. 130 mm |
Special features:
- Extremely stable in the long term
- Analog output 4...20 mA for dew point
- Condensation-resistant
- Quick adaption time
- Pressure-tight up to 350 bar (special version)
- NEW: Modbus-RTU interface
- NEW: Higher resolution of sensor signal due to the improved evaluation electronics