Flow meter for compressed air and gases VA 500 with display

€2,062.00

Net

€2,453.78*

Product number: 0695 5001
Product information "Flow meter for compressed air and gases VA 500 with display"
Flow meter for compressed air and gases VA 500 with display

Items of Flow meter for compressed air and gases VA 500 with dispaly

 
Product Description Order No.
VA 500 consumption probe in the basic version: standard (92.7 m/s), probe length 220 mm, without display   0695 5001
Display   Z695 5000

Special features volume flow measurement

  • Including temperature measurement
  • RS 485 interface, Modbus-RTU as standard
  • Integrated display for m3/h and m3
  • Applicable from 1/2" to DN 1000
  • Easy installation under pressure
  • 4...20 mA analogue output for m3/h or m3/min
  • Pluse output for m3 or M-bus (optional)
  • Inner diameter adjustable by means of keys
  • Flow meter can be reset
  • Adjustable by means of keypad on the display: Refrence conditions, °C and mbar, 4...20 mA scaling, pluse weight

Technical Data VA 500

Parameters m3/h, l/min (1000 mbar, 20 °C) in case of compressed air or Nm3/h, Nl/min (1013 mbar, 0 °C) in case of gases
Units adjustable via keys at display m3/h, m3/min, l/min, l/s, ft/min, cfm, m/s, kg/h, kg/min, g/s, lb/min, lb/h
Adjustable via keypad Diameter for volume flow calculation, counter resettable
Sensor Thermal mass flow sensor
Measured medium Air, gases
Gas types are adjustable over CS service software or CS data logger Air, nitrogen, argon, helium, CO2, oxygen, vacuum
Measuring range See Measuring range table
Accuracy (m.v: of meas. value) (f.s.: of full scale) ±1.5% of m.v. ± 0.3% of f.s.
on request: ±1% of m.v. ± 0.3% of f.s.
Operating temperature -30... 110°C sensor tube
-20...+70°C housing
Operating pressure -1...50 bar (for pressure > 10 bar order additional high-pressure protection)
Digital output RS 485 interface, (Modbus-RTU), optional: Ethernet interface PoE, M-Bus
Analogue output 4...20 mA for m3/h or l/min
Pluse output 1 pulse per m3 or per litre electrically isolated. Pluse weight can be set on the display. Alternatively, the pluse output can be used as an alarm
Supply 18...36 VDC, 5 W
Burden < 500 Ω
Housing Polycarbonate (IP 65)
Sensor tube Stainless steel, 1.4301 Installation length 220 mm, Ø 10 mm
Mounting thread G 1/2", G 1/2" NPT male thread
Ø housing 65 mm
Mounting position any
 
Flow measuring ranges VA 500 for compressed air (ISO 1217: 1000 mbar, 20°C) 
Inside diameter of pipe VA 500 Standard (92.7 m/s) VA 500 Max. (185.0 m/s) VA 500 High-Speed (224.0 m/s)
Inch mm   Measuring range full scale Measuring range full scale Measruting range full scale
      m3/h (cfm) m3/h (cfm) m3/h (cfm)
1/2" 16.1 DN 15 759 l/min 26 1516 l/min 53 1836 l/min 64
3/4" 21.7 DN 20 89 m3/h 52 177 m3/h 104 215 m3/h 126
1" 27.3 DN 25 148 m3/h 86 294 m3/h 173 356 m3/h 210
1 1/4" 36.0 DN 32 266 m3/h 156 531 m3/h 312 643 m3/h 378
1 1/2" 41.9 DN 40 366 m3/h 215 732 m3/h 430 886 m3/h 521
2" 53.1 DN 50 600 m3/h 353 1197 m3/h 704 1450 m3/h 853
2 1/2" 68.9 DN 65 1028 m3/h 604 2051 m3/h 1207 2484 m3/h 1461
3" 80.9 DN 80 1424 m3/h 838 2842 m3/h 1672 3441 m3/h 2025
4" 110.0 DN 100 2644 m3/h 1556 5278 m3/h 3106 6391 m3/h 3761
5" 133.7 DN 125 3912 m3/h 2302 7808 m3/h 4594 9453 m3/h 5563
6" 159.3 DN 150 5560 m3/h 3272 11096 m3/h 6530 13436 m3/h 7907
8" 200.0 DN 200 8785 m3/h 5170 17533 m3/h 10318 21229 m3/h 12493
10" 250.0 DN 250 13744 m3/h 8088 27428 m3/h 16141 33211 m3/h 19544
12" 300.0 DN 300 19814 m3/h 11661 39544 m3/h 23271 47880 m3/h 28177

Comparison of Flow meter with display and without display
The main difference between a flow meter VA 500 with display and a flow meter VA 500 without display is the presence of a display screen on the device. The flow meter VA 500 with display will have a built-in screen that shows real-time flow rate readings, totalized flow volume, and possibly other relevant information. This makes it easier for the user to monitor and track the flow measurements directly on the device.
On the other hand, the flow meter VA 500 without display will not have a built-in screen, so the user will need to connect it to an external display or monitoring system to view the flow rate and other data. This may require additional equipment and setup but can be a cost-effective option for applications where a separate display is already available.
In summary, the main difference is the presence or absence of a display screen on the flow meter itself, which affects how the flow data is displayed and accessed by the user.