Air-to-cooled mass heat exchangers
The precooled air enters the heat exchanger from air to cool where it is cooled to the required dew point by exchanging heat in countercurrent with the cold mass thermal fluid, allowing for maximum heat exchange.
Refrigeration dryer DRYBERG | DRYBERG®️ RF39/AC |
Volume flow (m3/h) at +3 °C | 2208 |
Power consumption (kW) | 3,80 |
Pressure loss (Δp bar [g]) | 0,13 |
Air connection (ø) | DN80-PN16 |
Dimensions AxBxC (mm) | 1465x790x1000 |
Weight (kg) | 290 |
In the case of divergent operating pressure: Divide volume flow by factor
bar (g) | 4 | 5 | 6 | 7 | 8 | 10 | 12 | 14 |
Correction factor | 0.77 | 0.86 | 0.93 | 1.00 | 1.05 | 1.14 | 1.21 | 1.27 |
°C | 25 | 30 | 35 | 40 | 45 | 50 |
Correction factor | 1.00 | 0.96 | 0.91 | 0.85 | 0.76 | 0.64 |
°C | 25 | 30 | 35 | 40 | 45 | 50 | 55 | 60 | 65 | 70 |
Correction factor | 1.27 | 1.21 | 1.00 | 0.84 | 0.70 | 0.57 | 0.48 | 0.42 | Auf Anfrage |
°C | 3 | 5 | 7 | 10 |
Correction factor | 1.00 | 1.09 | 1.19 | 1.37 |