Enhance Your Operations with Advanced Adsorption Air Dryer Heat Regenerated Systems
Adsorption Air Dryer DRYBERG®️ ADP including:
• Switch over control (proximity switches for valves K1 and K2)
Capacity volume flow: up to 9500 m3/h*
Pressure dew point: -40°C
Media: compressed air, gases of fluid group 2
max. operating pressure: 11 bar g (size ADP1400 ... ADP5000)
10 bar g (size ADP6000 ... ADP 9500)
min. operating pressure: 4 bar g
Connection: flange acc. DIN EN 1092-1 (DIN 2633)
Capacity* [m3/h] | 8200 |
Connection [inch] | DN150 |
Dimensions (AxBxC) [mm] | 3600x2500x3100 |
Weight [kg] | 8000 |
Required PDP | -40°C |
Operating pressure [bar] |
7
|
Inlet temperature [°C] |
40
|
Operating pressure (bar g) | ||||||||
4 | 5 | 6 | 7 | 8 | 9 | 10 | ||
Inlet
Temp.(°C) |
30 | 0,71 | 0,86 | 1 | 1,15 | 1,18 | 1,25 | 1,37 |
35 | 0,62 | 0,75 | 0,87 | 1 | 1,12 | 1,25 | 1,37 | |
40 | 0,38 | 0,53 | 0,67 | 0,82 | 0,92 | 1,07 | 1,21 | |
43 | --- | 0,33 | 0,45 | 0,54 | 0,61 | 0,72 | 0,80 |