Heatless Adsorption system
When the vessel in adsorption phase becomes saturated, detected by rising dew point (dew point control mode) or when the time setting for adsorption is reached (time control mode), the switch over process is initiated automatically. The regenerated vessels enters the adsorption phase, while the just saturated vessels enters the desorption phase.
Capacity* [m3/h] | 6000 |
Connection [inch] | DN150 |
Dimensions (AxBxC) [mm] | 3400x2350x3000 |
Weight [kg] | 6300 |
Required PDP | -40°C |
Operating pressure [bar] |
7
|
Inlet temperature [°C] |
40
|
Operating pressure (bar g) | ||||||||
4 | 5 | 6 | 7 | 8 | 9 | 10 | ||
Inlet
Temp.(°C) |
30 | 0,71 | 0,86 | 1 | 1,15 | 1,18 | 1,25 | 1,37 |
35 | 0,62 | 0,75 | 0,87 | 1 | 1,12 | 1,25 | 1,37 | |
40 | 0,38 | 0,53 | 0,67 | 0,82 | 0,92 | 1,07 | 1,21 | |
43 | --- | 0,33 | 0,45 | 0,54 | 0,61 | 0,72 | 0,80 |