METPOINT®️ FLM SF53 with BDL compact

Net €4,140.00

€4,926.60*

Product number: 4031323
Product information "METPOINT®️ FLM SF53 with BDL compact"
METPOINT®️ FLM SF53 with BDL compact - volume flow measurement

- Sensor SF53, 185 m/s, 220 mm insertion depth
- Datenlogger BDL compact 2D
- Connection cable approx. 5 m

 

FLM: Sensor technology for volume flow measurement

Every third compressor is only operated to compensate for air losses. These costs are largely avoidable. One possibility to avoid these costs is precise acquisition of the current volume flow. This then provides the basis for many important analyses, documentation and decisions. BEKO TECHNOLOGIES provides end-position monitoring with the METPOINT FLM SF13 and SF53

 
Is your production set up as optimally economical?

You can only comprehensively answer this question when the current volume flowrequirement for your compressed air has been identified. This can be evaluated for you by the METPOINT FLM volume flow measuring system and thereby provides you with the data basis you need for intelligent energy management. Identify potential savings, overloads and weak points in your system to improve its efficiency. By measuring the actual flow to the various production units, you are in a position to make decisions based on facts. At the same time, the METPOINT FLM lets them know whether there are any leaks in their system. The measurement thereby provides you with all the necessary data you need to jointly coordinate components in the best possible way and design systems economically. 

The METPOINT®️ FLM SF13 variant is available with measuring sections of different diameters and comes with a calibration certificate for the selected pipe diameter. The SF53 is pre-calibrated as a universal sensor to a pipe diameter of 53.1 mm, but can be adjusted/calibrated to other diameters on customer request.

Model with display

With the display and configuration menu, all measured values can be displayed and sensor settings can be made

Model with LED

The less expensive LED variant indicates the need for a new calibration (annually). Please note: The sensor configuration can only be done during production or later via the BDL datalogger

Function FLM

Two temperature sensors are installed in series in the direction of flow. The first temperature sensor measures the current process temperature of the compressed air, while the second sensor is electrically heated to a temperature that is 40 K higher than that of the first sensor. Higher volume flows results in a quicker drop in temperature at the sensors, so that the electric heater of the second sensor must increase its heat output. The electric energy required to maintain the temperature difference is proportional to the volume flow. This energy consumption is converted to provide the relevant flow measurements. 

 

Technical Data Flowsensor SF53

Dimensions (mm)
220 mm insertion depth
80 x 437 x 94 (width | height | depth)
Operating temperature -30 ... +140 ° C Sensor tube, -30 ... +80 ° C Housing
Power supply 18 ... 36 VDC through optional power adapter or  BDL
Measuring technique Calorimetric
Media Air, gases
Humidity of the medium Max. 90% r.F. (no droplets)
Operating pressure 0 ... 10 bar (e), 0 ... 50 bar (e) with additional pressure protection
Material sensor tube and fittings 1.4301 Stainless steel
Digital output RS485 (Modbus RTU)
Analog output 4 ... 20 mA (load <500 Ω)
Pulse output 1 pulse per m³ or per litre, floating pulse.
Passive: max. 48 VDC 150 mA
 
 
METPOINT BDL compact: the cost-effective solution
The METPOINT BDL compact compact is equipped with two to four sensor inputs optionally analog, digital or mixed. Two additional digital or analogue inputs are optionally available on request - e.g. for electricity meters or pressure sensors. Critical points in your processes are then displayed immediately. This reduces your reaction time and increases process and production safety levels. The compact screen recorder optionally provides a data logger with a 4 GB memory capacity.

 




Downloads
Technical Data METPOINT®️ FLM SF53 with display , PDF( Size: 1.7 MB )
Catalog METPOINT®️ FLM SF53 with BDL compact , PDF( Size: 491 KB )






0 of 0 reviews

Leave a review!

Share your experiences with other customers.