Leak detector with camera LD 510

€4,045.00

Net

€4,813.55*

Product number: 06010106
Product information "Leak detector with camera LD 510"
Leak detector with camera LD 510

Leak detector with camera – indicates leakage rate in l/min

The new leak meters LD 500/510 with integrated camera and leakage calculation are ideal measuring instruments which help to find and document even smallest leakages (0.1 l/min corresponds to approx. 1 € p. a.) easily even in far distances.
LD 510 is the world’s first leakage meter with an additional freely assignable sensor input for all CS sensors. In addition to leakage measurement and detection, all necessary measurements relating to dew point, flow, pressure, temperature, ... can also be carried out.
Description Order No.
LD 510 set consisting of: 0601 0106
LD 510 leak detector incl. acoustic trumpet, with integrated camera and additional input for external sensors, 100 leak tags for marking the leaks on site 0560 0106
Integrated laser distance measurement Z554 5000
Transport case 0554 0106
Sound-proof headset 0554 0104
Focus tube with focus tip 0530 0104
AC adapter plug 0554 0009
Spiral cable for connecting the ultrasonic sensor, length 2m (extended) 020001402
Holster with shoulder strap for LD 500/510 020001795

Special features of leak detector LD 500/LD 510

  • Find out your leak size (l/min) and potential saving (€/year)
  • Find the smallest leaks in far distance
  • Auto level: Auto adapts the sensitivity automatically to the environment and eliminates the ambient noise reliably
  • Photograph leaking parts
  • Describe the leak and necessary actions
  • Transmit the leak details via USB to your desktop software
  • Create an ISO 50001 report
  • Seek the leak the whole day (9 hours)

Technical Data Leak detector with camera LD 510

Operating frequency 40 kHz ± 2 kHz
Connections 3.5 mm stereo jack for headset, power supply socket for connecting an external charger
Laser Wavelength: 645…660 nm
Output power: <1mW(laser class 2)
Power supply Output voltage: 24 VDC ± 10%
Output current: 120 mA in continuous operation
Display 3.5" touch screen
Interface USB interface
Data logger 16 GB SD memory card (100 million values)
Power supply Internal rechargeable Li-Ion batteries, approx. 9 h continuous operation, 4 h charging time
Ambient temperature 0…+50 °C
EMC DIN EN 61326
Auto level Automatically adapts the sensitivity to the environment and reliably eliminates ambient noise
Sensitivity min: 0.1 l/min at 6 bar, 5 m distance, approx. € 1/year of compressed air costs
Weight without headset 540 grams

Technical Data Of External Sensor Input (LD 510 only)

Measuring range: See external CS sensors
Accuracy: See external CS sensors
Power supply: Output voltage: 24 VDC ± 10%
Output current: 120 mA in continuous operation

A leak detector can be used to measure compressed air in a few different ways:
  1. Leak Detection: The primary function of a leak detector is to identify and locate leaks in a compressed air system. By using the detector to scan the system, operators can pinpoint areas where air is escaping and quantify the size and severity of the leaks. This measurement can help prioritize repairs and maintenance efforts to minimize energy loss and improve system efficiency. 
  2. Pressure Drop Measurement: A leak detector can also be used to measure pressure drops within the compressed air system. By comparing pressure readings at different points in the system, operators can identify areas where leaks are causing pressure losses and impacting overall performance. This measurement can help assess the effectiveness of leak repairs and verify system integrity. 
  3. Air Flow Rate Calculation: Some advanced leak detectors may have the capability to calculate the flow rate of air escaping from leaks in the system. By measuring the rate of air leakage, operators can estimate the volume of compressed air wasted due to leaks and quantify the associated energy costs. This measurement can help justify investments in leak detection and repair initiatives by demonstrating potential savings.
Overall, using a leak detector to measure compressed air can provide valuable insights into the performance and efficiency of the system. By quantifying leaks, pressure drops, and air flow rates, operators can make informed decisions to optimize their compressed air systems, reduce energy consumption, and improve overall productivity.


Downloads
Data sheet LD 500/510, PDF (Size: 2.1 MB)
Short manual LD 500, PDF (Siza:1 MB)
Suitable sensors - portable for LD 510, PDF (Size: 1.4 MB)
Instruction manual LD 500, PDF (Size: 2.5 MB)
Instruction manual CS Leak Reporter, PDF (Size: 1.6 MB)

0 of 0 reviews

Leave a review!

Share your experiences with other customers.