Minimum installation requirements:
• The load-bearing zone must be even, horizontal and able to bear the weight of the dryer.
• Minimum ambient temperature +1°C.
• Maximum ambient temperature +50°C.
• Ensure a proper cooling air replacement.
• Allow a sufficient clearance on each side of the dryer for proper ventilation and to facilitate maintenance operations. The dryer does not require attachment to the floor surface.
Refrigeration dryer | DRYBERG®️ RF13/AC |
Volume flow (m3/h) at +3 °C | 780 |
Power consumption (kW) | 1,40 |
Pressure loss (Δp bar [g]) | 0,20 |
Air connection (ø) | G 2" BSP-F |
Dimensions AxBxC (mm) | 975x555x625 |
Weight (kg) | 94 |
Operating pressures multiply air flow with correction factor f1
bar (g) | 4 | 5 | 6 | 7 | 8 | 10 | 12 | 14 |
f1 | 0.77 | 0.86 | 0.93 | 1.00 | 1.05 | 1.14 | 1.21 | 1.27 |
Ambient air temperatures multiply air flow with correction factor f2
°C | 25 | 30 | 35 | 40 | 45 |
f2 | 1.00 | 0.95 | 0.88 | 0.79 | 0.68 |
Compressed air inlet temperatures multiply air flow with correction factor f3
°C | 25 | 30 | 35 | 40 | 45 | 50 | 55 |
f3 | 1.20 | 1.11 | 1.00 | 0.81 | 0.67 | 0.55 | 0.45 |