Product information "BEKOMAT® 6 CO EX BEKO condensate drain "
Condensate discharge without compressed air loss
If a float drain becomes leaky, high costs arise due to air losses. Time-controlled solenoid valves also cause compressed air losses. During valve opening, valuable compressed air escapes unused into the environment. In contrast, a condensate drain with electronic level control ensures discharge without compressed air loss, thus without energy loss. This not only saves energy and costs but also reduces CO2 emissions. This is highly efficient condensate drainage without compressed air loss.
For reliable operation and efficient maintenance, suitable service units and spare parts for BEKOMAT® 6 are available to ensure long-term performance.
Function of BEKOMAT® 6 CO EX
Condensate flows through the inlet opening and collects in the container. The diaphragm valve remains closed due to pressure equalisation above the membrane.
Filled condition:
When the container is filled, the capacitive level sensor signals maximum level. The solenoid valve switches, relieving pressure above the diaphragm. The valve opens and condensate is discharged without compressed air loss. In case of malfunction, an alarm mode is triggered.
Accessories
All articles in this group