NITROBERG® 1000 Nitrogen Generator

€27,690.00

Net

€32,951.10*

Product number: 1020201000
Product information "NITROBERG® 1000 Nitrogen Generator "
Nitrogen Generator NITROBERG® 1000
23.4 Nm3/h (99.99%)


Capacity (Nm3/h)
Nitrogen content 97% 98% 99% 99,5% 99,9% 99,99% 99,995% 99,999%
Capacity Nm3/h  83.2 75.2 63.4 51.5 37.2 23.4 16.6 10.6
Compressed air factor 2.3 2.3 2.6 2.9 3.3 4.7 5.2 6.2
Compressed air Nm3/h 191.4 173.0 164.8 149.4 122.8 110.0 86.3 67.8
Compressed air m3/h * 205.4 185.6 176.9 160.3 131.7 118.0 92.6 72.8
Product vessel (l)  750 750 750 750 500 500 500 500
Compressed air vessel(l)  1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000

Technical Data of Nitrogen Generator NITROBERG® 1000

Nitrogen Generator NITROBERG® 1000
Part No.  1020201000
Dimensions  750x1200x2230 LxWxH (mm) 
Design pressure  11 bar 
Operating pressure  7 bar 
Net weight  859 kg 
Noise level  55 max 85 dB (A) 
Ambient temperature  +5 to +40 °C 
Electrical connection  230V 50Hz 110V 60 Hz 
Power consumption  150 W 
Safety class  54 IP 
Inlet Filtration **    0.01 micron 
Inlet filtration ** (Active carbon filter)  0.003 micron 
Outlet Filtration ** 3 to 5 micron 
Temperature *  20 ° C 
Above Sea Level *  0 m 
Pressure *  1.0133 bar 
Humidity * 70%
   
* Consult us for performance under other specific conditions
** Optional

Installation requirements for nitrogen PSA generators:

Installing a nitrogen PSA generator requires considerations such as space availability, electrical power supply, ventilation, and access for maintenance. Installation must be done according to the instructions provided by us and may require professional assistance. Be sure that we will not leave you alone during the installation and maintenance process and we will always be by your side.
When installing a nitrogen PSA generator, several factors need to be taken into consideration to ensure optimal performance and safety. Here are some key points to elaborate on the installation requirements mentioned in the paragraph:

  1. Space Availability: Nitrogen PSA generators come in various sizes, so it's essential to have enough space to accommodate the unit. The installation location should provide adequate clearance around the generator for ventilation and maintenance access. Additionally, consider factors such as proximity to other equipment or potential obstructions that could impact the operation of the generator. 
  2. Electrical Power Supply: Nitrogen PSA generators require a stable and sufficient electrical power supply to operate effectively. Ensure that the installation location has access to the appropriate voltage and current requirements specified by the manufacturer. It's crucial to follow electrical safety guidelines during installation to prevent any hazards or malfunctions. 
  3. Ventilation: Proper ventilation is essential for nitrogen PSA generators to dissipate heat and maintain optimal operating conditions. The installation site should have adequate airflow to prevent overheating and ensure efficient performance. Additionally, consider any ventilation requirements specified by the manufacturer to maintain purity levels and prevent contamination. 
  4. Access for Maintenance: Accessibility for maintenance tasks is crucial for ensuring the longevity and efficiency of the nitrogen PSA generator. The installation location should allow easy access to key components for routine inspections, servicing, and repairs. Following manufacturer guidelines for maintenance procedures is essential to prevent issues and prolong the lifespan of the generator. 
  5. Professional Assistance: Due to the complexity of nitrogen PSA generator systems, it is recommended to seek professional assistance for the installation process. Qualified technicians have the expertise and experience to properly set up the generator according to manufacturer guidelines, ensuring safe and efficient operation. Additionally, professional installation can help prevent potential issues that may arise from incorrect setup.
In general, compliance with the NITROBERG® nitrogen generator installation requirements and instructions provided by BERG Kompressoren GmbH at the time of purchase and installation is essential for the successful deployment of your PSA nitrogen generator.
By considering factors such as space availability, electrical power supply, ventilation, and access for maintenance, operators can ensure optimal performance and reliability of the generator in industrial applications. And with the support of BERG Kompressoren GmbH services , you can rest assured that we will be there to assist you every step of the way, providing guidance and expertise to help you get the most out of your NITROBERG® nitrogen PSA generator.


Downloads 
Technical Data Nitrogen Generator NITROBERG® 1000, PDF( Size: 82 kB )

0 of 0 reviews

Leave a review!

Share your experiences with other customers.