PUREBERG® Z - V, Oil-free Package

Activated carbon tower for activated carbon tower for oil-free solution (PUREBERG® Z-V)

BERG compressors always try to offer the customer the best solution to make the process easier, more reliable and safer. You can find many types of comprehensive information on controlled air treatment processes to reliably remove condensate or other liquids from the compressed air system. The best time to change the filter or even consider the energy cost of each filter in your compressed air line.
Our PUREBERG® Accesoreies can be used in a variety of applications.
PUREBERG® Z 150 V Activated carbon tower
Activated carbon tower PUREBERG® Z 150 V Technical Data of PUREBERG® Z 150 V Capacity* [m3/h] 150 Connection [inch] 1" Dimensions (AxCxD) [mm] 1202x696x575 Weight [kg] 80 Ambiant temperature [°C] min. +5 / max. +50 Max. operating pressure [bar g] 16 Pressure dew point better than 8 °C Residual oil content at 20 °C [mg/m³] 0,01 Inlet temperature [°C] 40 *based on 1 bar (abs.) and 20°C at 7 bar g operating pressure     Operating pressure (bar g)   4 5 6 7 8 9 10 11 12 13 14 15 16 K1 0,6 0,7 0,8 1 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 2   Downloads Technical data sheet of Activated carbon tower PUREBERG® Z 150 V, PDF( Size: 1.5 MB ) Operating Manual oil vapour adsorber PUREBERG® ZV, PDF( Size: 700 KB )

Net €3,810.00 €4,533.90*
PUREBERG® Z 180 V Activated carbon tower
Activated carbon tower PUREBERG® Z 180 V Technical Data of PUREBERG® Z 180 V Capacity* [m3/h] 180 Connection [inch] 1" Dimensions (AxCxD) [mm] 1382x696x575 Weight [kg] 89 Ambiant temperature [°C] min. +5 / max. +50 Max. operating pressure [bar g] 16 Pressure dew point better than 8 °C Residual oil content at 20 °C [mg/m³] 0,01 Inlet temperature [°C] 40 *based on 1 bar (abs.) and 20°C at 7 bar g operating pressure     Operating pressure (bar g)   4 5 6 7 8 9 10 11 12 13 14 15 16 K1 0,6 0,7 0,8 1 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 2   Downloads Technical data sheet of Activated carbon tower PUREBERG® Z 180 V, PDF( Size: 700 KB ) Operating Manual oil vapour adsorber PUREBERG® ZV, PDF( Size: 700 KB )

Net €4,280.00 €5,093.20*
PUREBERG® Z 210 V Activated carbon tower
Activated carbon tower PUREBERG® Z 210 V Technical Data of PUREBERG® Z 210 V Capacity* [m3/h] 210 Connection [inch] 1" Dimensions (AxCxD) [mm] 1506x696x575 Weight [kg] 95 Ambiant temperature [°C] min. +5 / max. +50 Max. operating pressure [bar g] 16 Pressure dew point better than 8 °C Residual oil content at 20 °C [mg/m³] 0,01 Inlet temperature [°C] 40 *based on 1 bar (abs.) and 20°C at 7 bar g operating pressure     Operating pressure (bar g)   4 5 6 7 8 9 10 11 12 13 14 15 16 K1 0,6 0,7 0,8 1 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 2   Downloads Technical data sheet of Activated carbon tower PUREBERG® Z 210 V, PDF( Size: 330 KB ) Operating Manual oil vapour adsorber PUREBERG® ZV, PDF( Size: 700 KB )

Net €4,840.00 €5,759.60*
PUREBERG® Z 340 V Activated carbon tower
Activated carbon tower PUREBERG® Z 340 V Technical Data of PUREBERG® Z 340 V Capacity* [m3/h] 340 Connection [inch] 1 1/2" Dimensions (AxCxD) [mm] 1540x696x700 Weight [kg] 163 Ambiant temperature [°C] min. +5 / max. +50 Max. operating pressure [bar g] 16 Pressure dew point better than 8 °C Residual oil content at 20 °C [mg/m³] 0,01 Inlet temperature [°C] 40 *based on 1 bar (abs.) and 20°C at 7 bar g operating pressure     Operating pressure (bar g)   4 5 6 7 8 9 10 11 12 13 14 15 16 K1 0,6 0,7 0,8 1 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 2   Downloads Technical data sheet of Activated carbon tower PUREBERG® Z 340 V, PDF( Size: 330 KB ) Operating Manual oil vapour adsorber PUREBERG® ZV, PDF( Size: 700 KB )

Net €5,330.00 €6,342.70*
PUREBERG® Z 480 V Activated carbon tower
Activated carbon tower PUREBERG® Z 480 V Technical Data of PUREBERG® Z 480 V Capacity* [m3/h] 480 Connection [inch] 1 1/2" Dimensions (AxCxD) [mm] 1639x696x700 Weight [kg] 173 Ambiant temperature [°C] min. +5 / max. +50 Max. operating pressure [bar g] 16 Pressure dew point better than 8 °C Residual oil content at 20 °C [mg/m³] 0,01 Inlet temperature [°C] 40 *based on 1 bar (abs.) and 20°C at 7 bar g operating pressure     Operating pressure (bar g)   4 5 6 7 8 9 10 11 12 13 14 15 16 K1 0,6 0,7 0,8 1 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 2   Downloads Technical data sheet of Activated carbon tower PUREBERG® Z 480 V, PDF( Size: 330 KB ) Operating Manual oil vapour adsorber PUREBERG® ZV, PDF( Size: 700 KB )

Net €5,330.00 €6,342.70*
PUREBERG® Z 600 V Activated carbon tower
Activated carbon tower PUREBERG® Z 600 V Technical Data of PUREBERG® Z 600 V Capacity* [m3/h] 600 Connection [inch] 1 1/2" Dimensions (AxCxD) [mm] 2099x696x700 Weight [kg] 217 Ambiant temperature [°C] min. +5 / max. +50 Max. operating pressure [bar g] 16 Pressure dew point better than 8 °C Residual oil content at 20 °C [mg/m³] 0,01 Inlet temperature [°C] 40 *based on 1 bar (abs.) and 20°C at 7 bar g operating pressure     Operating pressure (bar g)   4 5 6 7 8 9 10 11 12 13 14 15 16 K1 0,6 0,7 0,8 1 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 2   Downloads Technical data sheet of Activated carbon tower PUREBERG® Z 600 V, PDF( Size: 700 KB ) Operating Manual oil vapour adsorber PUREBERG® ZV, PDF( Size: 700 KB )

Net €6,420.00 €7,639.80*
PUREBERG® Z 820 V Activated carbon tower
Activated carbon tower PUREBERG® Z 820 V Technical Data of PUREBERG® Z 820 V Capacity* [m3/h] 820 Connection [inch] 2" Dimensions (AxCxD) [mm] 1891x860x845 Weight [kg] 341 Ambiant temperature [°C] min. +5 / max. +50 Max. operating pressure [bar g] 16 Pressure dew point better than 8 °C Residual oil content at 20 °C [mg/m³] 0,01 Inlet temperature [°C] 40 *based on 1 bar (abs.) and 20°C at 7 bar g operating pressure     Operating pressure (bar g)   4 5 6 7 8 9 10 11 12 13 14 15 16 K1 0,6 0,7 0,8 1 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 2   Downloads Technical data sheet of Activated carbon tower PUREBERG® Z 820 V, PDF( Size: 330 KB ) Operating Manual oil vapour adsorber PUREBERG® ZV, PDF( Size: 700 KB )

Net €7,780.00 €9,258.20*
PUREBERG® Z 1000 V Activated carbon tower
Activated carbon tower PUREBERG® Z 1000 V Technical Data of PUREBERG® Z 1000 V Capacity* [m3/h] 1000 Connection [inch] 2" Dimensions (AxCxD) [mm] 2119x860x845 Weight [kg] 391 Ambiant temperature [°C] min. +5 / max. +50 Max. operating pressure [bar g] 16 Pressure dew point better than 8 °C Residual oil content at 20 °C [mg/m³] 0,01 Inlet temperature [°C] 40 *based on 1 bar (abs.) and 20°C at 7 bar g operating pressure     Operating pressure (bar g)   4 5 6 7 8 9 10 11 12 13 14 15 16 K1 0,6 0,7 0,8 1 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 2   Downloads Technical data sheet of Activated carbon tower PUREBERG® Z 1000 V, PDF( Size: 800 KB ) Operating Manual oil vapour adsorber PUREBERG® ZV, PDF( Size: 700 KB )

Net €8,850.00 €10,531.50*
PUREBERG® Z 1200 V Activated carbon tower
Activated carbon tower PUREBERG® Z 1200 V Technical Data of PUREBERG® Z 1200 V Capacity* [m3/h] 1200 Connection [inch] 2" Dimensions (AxCxD) [mm] 2219x860x845 Weight [kg] 413 Ambiant temperature [°C] min. +5 / max. +50 Max. operating pressure [bar g] 16 Pressure dew point better than 8 °C Residual oil content at 20 °C [mg/m³] 0,01 Inlet temperature [°C] 40 *based on 1 bar (abs.) and 20°C at 7 bar g operating pressure     Operating pressure (bar g)   4 5 6 7 8 9 10 11 12 13 14 15 16 K1 0,6 0,7 0,8 1 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 2   Downloads Technische Daten des Aktivkohleadsorber PUREBERG® Z 1200 V, PDF( Size: 330 KB ) Betriebsanleitung Öldampf adsorbiert PUREBERG® ZV, PDF( Size: 700 KB )

Net €9,570.00 €11,388.30*
Oil Check Indicator, completely BERG
Oil Check Indicator, completely BERG The oil check indicator is a calibrated measuring instrument used to detect aerosol-mist levels of oil entrainment that may be present in compressed air systems. Sensitivity of the indicator is limited only by the total number of hours it is allowed to remain on the air supply system. The indicator is sensitive enough to measure a concentration of oil entrainment as low as 0.01 PPM (0.012mg/m3) in a compressed air system. It can be used in systems with line pressures between 10 and 125 PSIG (70 and 875 kPa).   Application Oil check indicator Oil entrainment in the control air supply to the pressure reducing valve may eventually have an adverse effect on the control system performance. Since some oil entrainment is inherent to lubricated compressor installations must include factory approved oil filters to be reliably acceptable.  The indicator can be used in two ways. Either it can be used to check for oil carryover from the compressor or it can be used to check out any filtered air supply source before connecting it to the system and also every few months after the system becomes operative. Once the needle valve of the oil indicator has been opened, one continuous uninterrupted exposure is recommended foe greatest accuracy. Operation Oil check indicator When the needle valve of the oil indicator is open, less than 2 SCIM/PSIG (0.08 ml/s/kPa) will flow through the calibrated plastic tube. Any oil present in the air will then carry a red oil soluble dye up the tube, coloring a white material in the tube. The rate of color travel will be proportional to the amount of oil present. The parts per million (PPM) valve of oil entrained in the sir can be determined using the conversion chart included with the instrument. After use, the needle valve should be closed and left in the line and the cartridge removed. At the time of the next test, a replacement cartridge will need to be installed on the needle valve fitting.   Installation Oil check indicator In order for the oil indicator to properly measure a given oil entrainment, sufficient exposure time is required. The length of exposure time is inversely proportional to the pressure at the point of installation. When using the indicator to check for oil carryover from the compressor, it should be installed at the discharge of the tank. When using the indicator to measure oil entrainment in the air supply system, it should be installed between the oil filter and the pressure reducing valve (PRV). At this point, dry high pressure air will be present, resulting in the best accuracy and fastest indication.   Technical Data of Oil Check Indicator   Oil Check Indicator BERG   Air consumption 1.9 SCIM/PSIG (0.07 mL/s/kPa) Max. temperature rating [°C] 49 Pressure range 10 - 125 PSIG Oil concentration Range [mg/m3] 0 - 30 Accessory Oil indicator replacement cartridge Mass [kg] 0.200 Downloads Oil Check Indicator Instructions for installation and operation  , PDF( Size: 332 KB )

Net €238.00 €283.22*
Oil Check Indicator Replacement test tube BERG
Oil Check Indicator Replacement test tube BERG   Use of oil check indicator To assess the compressed air temperature, an adapter (1) with an oil check indicator is mounted on the head of the filter/absorber. When the needle valve (3) is opened fully, a specific volumetric flow will pass through the detector tube (5). The oil residues in the compressed air cause the detector tube to turn red from the bottom upwards.   Important information : 1. The oil check unit is designed to allow measurement without danger to operating personnel. However, prior to measurement it must be checked that the detector tube connection (4) is firmly screwed on before opening the needle valve (3). 2. The unit incorporates a pressure reducer (2) upstream of the needle valve (3) to reduce the pressure at the detector tube to a maximum of 7 bar. With higher operating pressures, 7 bar should therefore always be used as the standard value for the determination of the oil content. 3. The usability period of the oil check indicator is limited by the measurement duration (several days or continuous in the case of low oil contamination) and the oil content of the compressed air. When the detector tube has turned red from bottom to top, it will need to be replaced: - Close needle valve (3) - undo threaded connection (4) - install new detector tube (5) 4. When the oil check indicator is used in areas with moist compressed air, a pink coloured section will appear above the red coloured section. This pink section should not be taken into account for the assessment of the oil load. 5. The oil check indicator must be mounted in a vertical position.   Technical Data of Oil Check Indicator   Oil Check Indicator BERG   Air consumption 1.9 SCIM/PSIG (0.07 mL/s/kPa) Max. temperature rating [°C] 49 Pressure range 10 - 125 PSIG Oil concentration Range [mg/m3] 0 - 30 Accessory Oil indicator replacement cartridge Mass [kg] 0.200 Downloads Oil Check Indicator Instructions for installation and operation  , PDF( Size: 332 KB )

Net €202.00 €240.38*

Technical data of PUREBERG® Z 150 -1200 V

Type Connection Capacity Dimenstions (AxCxD) Pre filter Dust filter Weight
" m3/h mm     kg
Z 150 V 1" 150 1202 696 575 F 05FW F 05SW F 05DW 80
Z 180 V 1" 180 1382 696 575 F 05FW F 05SW F 05DW 89
Z 210 V 1" 210 1506 696 575 F 06FW F 06SW F 06DW 95
Z 340 V 1 1/2" 340 1540 696 700 F 09FW F 09SW F 09DW 163
Z 480 V 1 1/2" 480 1639 696 700 F 09FW F 09SW F 09DW 173
Z 600 V 1 1/2" 600 2099 696 700 F 13FW F 13SW F 13DW 217
Z 820 V 2" 820 1891 860 845 F 15FW F 15SW F 15DW 341
Z 1000 V 2" 1000 2119 860 845 F 20FW F 20SW F 20DW 391
Z 1200 V 2" 1200 2219 860 845 F 20FW F 20SW F 20DW 413