Oxygen Generator Packages – Complete PSA Systems on One Skid
OXYBERG® plug-and-play oxygen generation systems
An oxygen generator package combines the OXYBERG® PSA generator, dryer, filters, air and product-gas receivers, monitoring, piping and electrical wiring on one pre-assembled skid. A correctly sized screw compressor is available as an option. Models 500–1000 deliver 1.5–10.1 Nm³/h at 95% oxygen purity according to their datasheets. An oxygen booster and cylinder filling station can be added to the project scope.
BERG GaseTech manufactures the PSA technology; BERG Kompressoren engineers and integrates the complete system. Site connections, ventilation and commissioning are specified for your installation.
Oxygen Generators Skid Packages
Compare OXYBERG Complete Packages
| Package | O₂ at 93% purity (Nm³/h) | Compressor (optional) | L × W × H (mm) | Weight (kg) | Lead time | Datasheet |
|---|---|---|---|---|---|---|
| OXYBERG 500 Plug and Play | 1.7 | BSDK 5 or 7 | 2000 × 1000 × 1860 | 576 | On request | PDF ↗ |
| OXYBERG 600 Plug and Play | 2.4 | BSDK 5 or 7 | 2000 × 1000 × 1920 | 639 | On request | PDF ↗ |
| OXYBERG 700 Plug and Play | 4.2 | BSDK 7 or 11 | 2000 × 1000 × 1910 | 793 | On request | PDF ↗ |
| OXYBERG 800 Plug and Play | 5.5 | BSDKF 11 or 13 | 2000 × 2000 × 2000 | 1229 | On request | PDF ↗ |
| OXYBERG 900 Plug and Play | 8.2 | BSDKF 11 or 13 | 2000 × 2000 × 2260 | 1279 | On request | PDF ↗ |
| OXYBERG 1000 Plug and Play | 11.5 | BSDKF 15 or 13 | 2000 × 2000 × 2390 | 1368 | On request | PDF ↗ |
Data is taken from the linked standard datasheets. Dimensions and weight refer to the skid shown in those datasheets, without the optional compressor. The compressor is not included in the scope of supply; the suggested models do not constitute confirmation of power ratings in kW. Final equipment selection and lead time will be confirmed in the quotation.
What Components Make Up the Skid?
Functional overview; not a layout drawing to scale. The position of the optional compressor is determined individually for each project.
Complete Package or Individual Components?
| Criterion | Complete package | Individual components |
|---|---|---|
| Space requirements | Common base frame matched to the system; allow space for maintenance | Flexible positioning; plan clearances and pipework separately |
| Installation | Pipework and wiring prepared on the skid | Connect the components on site |
| Suppliers | BERG coordinates the agreed package scope | Coordinate components and their interfaces separately |
| Commissioning | Joint inspection of the integrated system | Verify that all components work together on site |
| Liability for defects | According to the quotation and agreed scope of supply | According to the respective supply contracts |
Price
The currently listed starting price for the OXYBERG® 500 complete package is €26,400 net, excluding VAT and shipping. The optional compressor is not included in the scope of supply stated in the standard datasheet. Purity, flow rate, outlet pressure, compressor selection, redundancy and optional boosters determine the project-specific total price.
Cylinder Filling Option
An oxygen-compatible booster, filling manifold, high-pressure pipework and the required safety functions can form part of a project-specific filling system. Filling pressure and capacity are determined according to the cylinders, demand and approved scope of supply. Approval for filling medical oxygen cylinders must be documented separately.
How a skid-mounted oxygen generation system works
A coordinated oxygen plant PSA package produces oxygen from ambient air directly at the point of use.
Design features and complete system advantages
OXYBERG® oxygen generation systems combine reliable engineering, intelligent control and continuous process monitoring with flexible skid integration.
Engineered for reliable oxygen production
- Siemens PLC and HMI process control
- Oxygen purity and pressure monitoring
- Adsorption dryer and compressed-air filtration
- Air and oxygen buffer receivers
- Pre-installed piping and electrical wiring
- Designed for continuous-duty operation
More than an oxygen generator
- Optional integrated air compressor
- Correctly sized buffer storage
- Remote monitoring and alarms
- Oxygen booster and cylinder filling
- Skid or container integration
- Commissioning and technical support
One package concept, multiple oxygen applications
Every process requires its own oxygen flow, purity, pressure, control philosophy and safety assessment.
Data required for an engineered proposal
Send the following operating information so that BERG can size the complete oxygen package.
- Required oxygen flow in Nm³/h
- Required oxygen purity and outlet pressure
- Daily operating hours and load profile
- Installation country, altitude and temperature
- Application and applicable standards
- Required redundancy or backup supply
- Indoor, skid-mounted or containerised installation
Oxygen Package FAQ
The linked standard package datasheets list the compressor as not included. BERG can add a suitable compressor or configure the skid for a compatible existing compressed-air supply.
The electrical supply is specified for the complete ordered configuration. The generator datasheet lists 230 V / 50 Hz or 110 V / 60 Hz; its power consumption is not the total consumption of the compressor, dryer and optional booster. Use the project electrical drawings and quotation for site connections.
An open standard skid should not be assumed suitable for outdoor installation. Weather protection, ventilation, frost protection and operating temperature must be checked. The package datasheets specify an ambient range of +5 to +40 °C.
The duration depends on package scope and site readiness. Foundations, utilities, ventilation and safety checks must be prepared. BERG confirms the commissioning scope and schedule in the project proposal.
Expansion requires a review of compressor capacity, air treatment, generator, storage, controls and available space. Increased output cannot be assumed to be available through a software change alone.
Filters, dryers, condensate drains, sensors and any compressor or booster require inspection and service. Intervals depend on operating hours, site conditions and the manuals for the selected components.
A container can suit projects without a suitable indoor technical room, outdoor installations requiring a protective enclosure, or transportable systems. Ventilation, climate control and maintenance access are engineered for the site.
The product information reviewed here does not establish approval of the standard package for filling medical oxygen cylinders. Before such use, the specific certified system scope, gas quality, required validation and applicable approvals must be documented.