Nitrogen Generator NITROBERG 1100
27.6 Nm3/h (99.99%)
Your advantages to buy NITROBERG nitrogen generator
- Nitrogen at any time and at any place
- Economical through low operating costs
- Sophisticated and reliable technology
- Exact purity for every application
- No long-term rental commitments
- Hardly any CO2 pollution for the environment
Nitrogen Generator NITROBERG
PROCESS:
The BERG pressure swing adsorption process separates the nitrogen molecules from the oxygen molecules. The high-purity nitrogen can now be used in a wide range of applications.
BENEFITS of Nitrogen Generator
- plug and play simple and constant nitrogen supply
- constant measurement of nitrogen purity
- savings from the very first minute
- low-maintenance, compact design
Calculation of the compressed air requirements
Multiplying the nitrogen capacity by the air factor indicated below gives the compressed air requirements.
Nitrogen content(%) |
97.00 |
98.00 |
99.00 |
99.50 |
99.90 |
99.99 |
Air factor |
2.3 |
2.3 |
2.6 |
2.9 |
3.3 |
4.7 |
Compressed air specification
Temperature range: +5 to +50°C
Air quality: ISO 8573.1, Class 1: dirt and oil, Class 4: water
Pressure dew point: +3°C
option of Nitrogen Generator
Inlet and outlet filtration
Capacity (Nm3/h)
Nitrogen content |
97% |
98% |
99% |
99,5% |
99,9% |
99,99% |
99,995% |
99,999% |
Capacity Nm3/h |
115.8 |
97.2 |
79.2 |
67.3 |
47.7 |
27.6 |
20.8 |
14.1 |
Compressed air factor |
2.3 |
2.3 |
2.6 |
2.9 |
3.3 |
4.7 |
5.2 |
6.7 |
Compressed air Nm3/h |
266.3 |
223.6 |
205.9 |
195.2 |
157.4 |
129.7 |
108.2 |
94.5 |
Compressed air m3/h * |
285.8 |
239.9 |
221.0 |
209.5 |
168.9 |
139.2 |
116.1 |
101.4 |
Product vessel (l) |
750 |
750 |
750 |
750 |
750 |
750 |
750 |
750 |
Compressed air vessel (l) |
1,000 |
1,000 |
1,000 |
1,000 |
1,000 |
1,000 |
1,000 |
1,000 |
Technical Data of Nitrogen Generator
Nitrogen Generator |
1100 |
Part No. |
1020201100 |
Dimensions |
840x1610x2150 LxBxH (mm) |
Design pressure |
11 bar |
Operating pressure |
7 bar |
Net weight |
908 kg |
Noise level |
55 max 85 dB (A) |
Ambient temperature |
+5 to +40 °C |
Electrical connection |
230V 50Hz 110V 60 Hz |
Power consumption |
150 W |
Safety class |
54 IP |
Inlet Filtration ** |
0.01 micron |
Inlet filtration ** (Active carbon filter) |
0.003 micron |
Outlet Filtration ** |
3 to 5 micron |
Temperature * |
20 ° C |
Above Sea Level * |
0 m |
Pressure * |
1.0133 bar |
Humidity * |
70% |
|
|
* Consult us for performance under other specific conditions
** Optional |
Downloads
Technical Data Nitrogen Generator NITROBERG 1100, PDF( Size: 82 kB )