Operating instructions in accordance with the 2014/68/EU Pressure Equipment Directive

The DRYPOINT® RA 20-960 compressed-air refrigeration dryer contains pressure equipment in the sense of the 2014/68/EU Pressure Equipment Directive. Therefore, the entire plant needs to be registered with the supervisory authority if required in accordance with the local regulations.
For the examination prior to the start-up and for periodic inspections, the national regulations need to be observed, such as the industrial safety regulation in the Federal Republic of Germany. In countries outside the EU, the respective regulations in force there need to be adhered to.
The proper use of pressure devices is the basic requirement for safe operation. As regards pressure devices, the following points need to be observed:
• The DRYPOINT® RA 20-960 compressed-air refrigeration dryer must only be employed within the pressure and temperature range limits indicated by the manufacturer on the name plate.
• No welding must be carried out on the pressure parts.
• The DRYPOINT® RA 20-960 compressed-air refrigeration dryer must neither be installed in insufficiently ventilated rooms nor near heat sources or inflammable substances. • To avoid fractures resulting from material fatigue, the refrigeration dryer should not be exposed to vibrations during operation.
• The maximum operating pressure indicated by the manufacturer on the name plate must not be exceeded. It is the installer's responsibility to install the appropriate safety and control devices. Prior to the start-up of the DRYPOINT® RA 20-960 compressed-air refrigeration dryer, the connected pressure generator (compressor etc.) must be set to the max. permissible operating pressure. The integrated safeguard needs to be checked by an approved inspection agency.
• The documents related to the DRYPOINT® RA 20-960 compressed-air refrigeration dryer (manual, operating instructions, manufacturer's declaration etc.) must be kept safe for future reference.
• No objects whatsoever must be installed at or placed on the DRYPOINT® RA 20-960 compressed-air refrigeration dryer and the connecting lines.
• Installation of the plant in frost-free places only.
• Operation of the plant is only permissible with fully closed and intact housing and cover panels. Operation of the plant with damaged housing/cover panels is prohibited.

Technical Data of Refrigeration dryer DRYBERG® RF08/AC equal to DRYPOINT® RA490/AC

Refrigeration dryer DRYBERG®️ RF08/AC
Volume flow (m3/h) at +3 °C 450
Power consumption (kW) 0,71
Pressure loss (Δp bar [g]) 0,25
Air connection (ø) G 1 1/2" BSP-F
Dimensions AxBxC (mm) 885x555x580
Weight (kg) 56


Operating pressures multiply air flow with correction factor f1
bar (g) 4 5 6 7 8 10 12 14
f1 0.77 0.86 0.93 1.00 1.05 1.14 1.21 1.27

Ambient air temperatures multiply air flow with correction factor f2
°C 25 30 35 40 45
f2 1.00 0.95 0.88 0.79 0.68

Compressed air inlet temperatures multiply air flow with correction factor f3
°C 25 30 35 40 45 50 55
f3 1.20 1.11 1.00 0.81 0.67 0.55 0.45