Refrigeration dryer DRYBERG®️ RF02/AC equals to DRYPOINT®️ RA110/AC
Environmentally friendly and easy to service
›› Use of environmentally and ozone-friendly refrigerant with a particularly favourable GWP value (Global Warming Potential)
›› Low-cost and fast maintenance
Technical Data of Refrigeration dryer DRYBERG® RF02/AC
Refrigeration dryer |
DRYBERG®️ RF02/AC |
Volume flow (m3/h) at +3 °C |
108 |
Power consumption (kW) |
0,31 |
Pressure loss (Δp bar [g]) |
0,13 |
Air connection (ø) |
G1 BSP-F |
Dimensions AxBxC (mm) |
740x345x420 |
Weight (kg) |
36 |
In the case of divergent operating pressure: Divide volume flow by factor
bar (g) |
4 |
5 |
6 |
7 |
8 |
10 |
12 |
14 |
Correction factor |
0.77 |
0.86 |
0.93 |
1.00 |
1.05 |
1.14 |
1.21 |
1.27 |
In the case of divergent ambient temperature: Divide volume flow by factor
°C |
25 |
30 |
35 |
40 |
45 |
50 |
Correction factor |
1.00 |
0.96 |
0.91 |
0.85 |
0.76 |
0.64 |
In the case of divergent inlet temperature: Divide volume flow by factor
°C |
25 |
30 |
35 |
40 |
45 |
50 |
55 |
60 |
65 |
70 |
Correction factor |
1.27 |
1.21 |
1.00 |
0.84 |
0.70 |
0.57 |
0.48 |
0.42 |
Auf Anfrage |
In the case of divergent pressure dew point: Divide volume flow by factor
°C |
3 |
5 |
7 |
10 |
Correction factor |
1.00 |
1.09 |
1.19 |
1.37 |
Downloads
Manual DRYBERG®️ RF/AC, PDF( Size: 5 MB )