Refrigeration dryer DRYBERG®️ RF110/AC equals to DRYPOINT®️ RA6600/AC
THERMAL STORAGE OPERATION FOR LOW AIR FLOWS
The refrigerant compressor cycles ON/OFF for maximum savings and reliability. Since the refrigeration capacity is greater than the load, the excess capacity cools the all-in-one exchanger that acts like a thermal storage.
• For high/medium flows, the dryer applies the Impulse Technology to regulate its drying capacity.
• For low air flows, the dryer utilizes the “thermal storage” operation.
Technical Data of Refrigeration dryer DRYBERG® RF110/AC
Refrigeration dryer |
DRYBERG®️ RF110/AC |
Volume flow (m3/h) at +3 °C |
6624 |
Power consumption (kW) |
10,80 |
Pressure loss (Δp bar [g]) |
0,26 |
Air connection (ø) |
DN150-PN16 |
Dimensions AxBxC (mm) |
1810x1300x1750 |
Weight (kg) |
940 |
In the case of divergent operating pressure: Divide volume flow by factor
bar (g) |
4 |
5 |
6 |
7 |
8 |
10 |
12 |
14 |
Correction factor |
0.77 |
0.86 |
0.93 |
1.00 |
1.05 |
1.14 |
1.21 |
1.27 |
In the case of divergent ambient temperature: Divide volume flow by factor
°C |
25 |
30 |
35 |
40 |
45 |
50 |
Correction factor |
1.00 |
0.96 |
0.91 |
0.85 |
0.76 |
0.64 |
In the case of divergent inlet temperature: Divide volume flow by factor
°C |
25 |
30 |
35 |
40 |
45 |
50 |
55 |
60 |
65 |
70 |
Correction factor |
1.27 |
1.21 |
1.00 |
0.84 |
0.70 |
0.57 |
0.48 |
0.42 |
Auf Anfrage |
In the case of divergent pressure dew point: Divide volume flow by factor
°C |
3 |
5 |
7 |
10 |
Correction factor |
1.00 |
1.09 |
1.19 |
1.37 |