Adsorption Dryer DRYBERG ADP6000
Heatless Adsorption system
Compressed air in a moisture-saturated condition enters the adsorption and passes through the desiccant of the vessel in adsorption phase from the bottom to the top.
When the vessel in adsorption phase becomes saturated, detected by rising dew point (dew point control mode) or when the time setting for adsorption is reached (time control mode), the switch over process is initiated automatically. The regenerated vessels enters the adsorption phase, while the just saturated vessels enters the desorption phase.
Technical Data of heatless Adsorption compressed air dryer DRYBERG ADP
Capacity* [m3/h] |
6000 |
Connection [inch] |
DN150 |
Dimensions (AxBxC) [mm] |
3400x2350x3000 |
Weight [kg] |
6300 |
Required PDP |
-40°C |
Operating pressure [bar] |
7
|
Inlet temperature [°C] |
40
|
Calculated at 1 bar (abs.) and 20°C at 7 bar g operating pressure and 35°C compressed air inlet temperature (saturated condition)
|
Operating pressure (bar g) |
|
4 |
5 |
6 |
7 |
8 |
9 |
10 |
Inlet
Temp.(°C)
|
30 |
0,71 |
0,86 |
1 |
1,15 |
1,18 |
1,25 |
1,37 |
35 |
0,62 |
0,75 |
0,87 |
1 |
1,12 |
1,25 |
1,37 |
40 |
0,38 |
0,53 |
0,67 |
0,82 |
0,92 |
1,07 |
1,21 |
43 |
--- |
0,33 |
0,45 |
0,54 |
0,61 |
0,72 |
0,80 |
Contact us
E-mail:Kundenservice@berg-kompressoren.de